Get Device Motion Detection Parameters - Imou Open Platform
getDeviceAlarmParam: Get device dynamic detection parameters
Function details
Obtain equipment dynamic inspection parameters.
Request address
https://openapi-[DataCenter].easy4ip.com/openapi/getDeviceAlarmParam
Minimum permissions required for sub-account token request
"Permission":"Config" "Resource":"cam:serial number:channel number"
Incoming parameter description
| Parameter name | Parameter type | Required or not | Default value | Legal value | Parameter description | | :------------- | :------------- | :-------------- | :------------ | :---------- | :--------------------------------------- | | | token | String | Yes | | | Administrator or sub-account accessToken | | deviceId | String | Yes | | | Device serial number | | channelId | String | Yes | | | Channel ID |
Sample input
{
"system":{
"ver":"1.0",
"appId":"lcdxxxxxxxxx",
"sign":"53306c63d849c3d89cd6de845513a509",
"time":1603355808,
"nonce":"8bdd6436-28c5-4237-9da9-c3188d5ed84d"
},
"id":"90ec9dd9-8081-47aa-8771-19904a5d3aa4",
"params":{
"deviceId":"TESTQWERXXXX",
"channelId":"0",
"token":"At_00000ad9e6e87f0142eb92e207aec46a"
}
}
Return data field description
| Field name | Field type | Field description | |
|---|---|---|---|
| row | Integer | The number of rows in the dynamic detection area (read-only, device capability) | |
| column | Integer | The number of columns in the dynamic detection area (read-only, device capability) | |
| sensitive | Integer | Sensitivity, value range is [0, 100] | |
| threshold | Integer | Area threshold, value range is [0, 100] | |
| region | String | Motion inspection area | |
Remarks: region: Each line of the motion detection area is represented by a 32-bit integer. Each bit of the integer corresponds to a unit block of the screen. 0 indicates the non-motion detection area, 1 indicates the motion detection area, and the left side of the screen corresponds to the high number of the number. • The corresponding relationship between the 32-bit integer and the coordinates of the motion detection screen is as follows: • Screen column: left --> right; corresponding digital digits: left (high) --> right (low) because there are only 22 columns in motion detection, corresponding to the low 22 digits of the number, and the high 10 digits are fixed with 0
Sample output
{
"result":{
"msg":"The operation was successful.",
"code":"0",
"data":{
"stall":1,
"column":22,
"sensitive":5,
"row":18,
"threshold":5,
"region":"4194303,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384,3216384"
}
},
"id":"90ec9dd9-8081-47aa-8771-19904a5d3aa4"
}