Get started
  • English
  • 简体中文
Official Site
Get started
  • English
  • 简体中文
Official Site
  • Get started
  • Concepts
  • Guides
  • Device capabilities & events
    • Browse by device type
    • Device capabilities
      • Common methods
      • Detection and alarms
        • Arming
          • detection.arming.enabled (Read arming switch)
          • detection.arming.enabled (Set arming switch)
          • detection.arming.debounceDuration (Read alarm debounce duration)
          • detection.arming.debounceDuration (Set alarm debounce duration)
          • detection.arming.triggerInterval (Read event trigger interval)
          • detection.arming.triggerInterval (Set event trigger interval)
          • detection.arming.interval (Read alarm interval)
          • detection.arming.interval (Set alarm interval)
          • detection.arming.roles (Read local linkage roles)
          • detection.arming.linkedDevice (Read linked-device alarm)
          • detection.arming.linkedDevice (Set linked-device alarm)
          • detection.arming.changed (Arming mode changed)
          • detection.arming.mode (Read arming mode)
          • detection.arming.mode (Set arming mode)
          • detection.arming.leaveDelay (Read leave-home delay)
          • detection.arming.leaveDelay (Set leave-home delay)
          • detection.arming.applyMode (Apply arming mode)
          • detection.arming.queryMode (Query arming mode)
        • Attention zone
        • People counting
        • Cry detection
        • Absence from post
        • Face recognition
        • Fall detection
        • Gesture call
        • Intrusion
        • Loitering
        • Minor detection
        • Person and vehicle mix
        • Motion detection
        • Video occlusion
        • Illegal parking
        • Person detection
        • Pet detection
        • PIR
        • License plate recognition
        • Vehicle guard
        • Siren
        • Voice SOS
        • Abnormal sound
        • Tripwire
        • Unoccupied detection
        • Vehicle
        • Door contact
        • Tamper
        • Gate accessory
        • Environment sensing
        • Target detection frame
      • Image
      • PTZ
      • Light
      • Recording
      • Audio
      • Media
      • Network
      • Power
      • Privacy
      • Call
      • Storage
      • System
      • Algorithm
      • Maintenance
      • Control
    • Events overview
    • Permission codes
    • Capability error codes
    • Alarm and capability messages
    • Capability FAQ
    • Legacy ability and push types
  • API reference
  • SDK and tools
  • Solutions
  • Platform and support
On this page
What it does
Request URL
Minimum permission
Request parameters
Request example
Response data fields
Response example
Error codes

detection.arming.debounceDuration (Read alarm debounce duration)

detection.arming.debounceDuration: Read alarm debounce duration

detection.arming.debounceDuration · Device and channel · Permission Config

What it does

Reads alarm debounce duration: repeated triggers within the window are merged to reduce alarm storms. Range 0–100, step 1, unit s. Distinct from event trigger interval (throttle) and alarm interval (report spacing)—do not mix them.

Request URL

POST https://openapi-[DataCenter].easy4ip.com/openapi/v2/device.property.get

Minimum permission

The administrator does not need an extra permission on a device they bound. A shared device needs the basic configuration permission. A bound sub-user does not. A sub-account needs Config. Omitting channelId on a channel-scope capability returns DV2007. Do not send channelId on device-scope capabilities. Mixing device and channel in one request returns DV2008.

Request parameters

NameTypeRequiredDescription
tokenStringyesaccessToken for administrator, sub-user, or sub-account
deviceIdStringyesDevice serial number
productIdStringnoOptional. If sent and it does not match the device model → DV2009
channelIdStringconditionalRequired for channel scope; omit for device scope
propertiesArrayyes["detection.arming.debounceDuration"]

Common request fields and the signature are in Development specification.

Request example

{
 "id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
 "system": {
 "ver": "1.0",
 "appId": "lcdxxxxxxxxx",
 "sign": "xjhCQBoJ9hRDsCjyDcHjtDNzRZ3ZJezcawsfWeiaoxU=",
 "time": 1706511734,
 "nonce": "f5a1ae2d-c09c-4d39-a744-83a5c2c653c2"
 },
 "params": {
 "token": "<yourAccessToken>",
 "deviceId": "TESTIPC000012345",
 "properties": [
 "detection.arming.debounceDuration"
 ]
 }
}

Response data fields

The value is in result.data.properties["detection.arming.debounceDuration"].

Integer 0–100, step 1, unit s.

Response example

{
 "id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
 "result": {
 "code": "0",
 "msg": "Operation is successful",
 "data": {
 "properties": {
 "detection.arming.debounceDuration": 1
 }
 }
 }
}

Error codes

Gateway and device error codes are in Global return codes.