Get started
  • English
  • 简体中文
Official Site
Get started
  • English
  • 简体中文
Official Site
  • Get started
  • Concepts
  • Guides
  • Device capabilities & events
    • Browse by device type
    • Device capabilities
      • Common methods
        • Using capabilities
        • device.capability.list (List capabilities)
        • device.property.get (Read properties)
        • device.property.set (Write properties)
        • Invoke a service
      • Detection and alarms
      • Image
      • PTZ
      • Light
      • Recording
      • Audio
      • Media
      • Network
      • Power
      • Privacy
      • Call
      • Storage
      • System
      • Algorithm
      • Maintenance
      • Control
    • Events overview
    • Permission codes
    • Capability error codes
    • Alarm and capability messages
    • Capability FAQ
    • Legacy ability and push types
  • API reference
  • SDK and tools
  • Solutions
  • Platform and support
On this page
What it does
Request URL
Minimum permission
Request parameters
Request example
Response data fields
Response example
Error codes

device.property.set (Write properties)

device.property.set: Write properties

What it does

Writes multiple configuration properties in one call. Different models use the same request body (full propertyId keys). Out-of-range values are rejected, not clamped. Do not mix device-level and channel-level properties in one request. A write timeout does not mean the write did not run on the device.

Request URL

POST https://openapi-[DataCenter].easy4ip.com/openapi/v2/device.property.set

Minimum permission

An administrator needs no extra permission on a device they bound. A bound sub-user needs none. For shared devices and sub-accounts, required permission follows each property page’s Minimum permission and Permission codes; the gateway checks internal capability codes—device.capability.list does not return shareAuthCode/subAccountAuthCode. Same rules as device.property.set. The device must be bound.

Request parameters

NameTypeRequiredDefaultAllowed valuesDescription
tokenStringyesAdministrator, sub-user, or sub-account accessToken
deviceIdStringyesDevice serial number
productIdStringnoOptional. If sent and it does not match the device model → DV2009
channelIdStringconditionalChannel index; IPCs often "0". Do not pass -1. Single-channel IPCs still use "0"Required for channel-level writes; omit for device-level. Mixing levels in one request returns DV2008
propertiesObjectyeskeys are full propertyIdValues to write. Switches: int 0/1. Enums: value. Struct inner keys use field. Members marked required in device.capability.list must be present on a full write; missing members → DV2014

Common request fields and signing: Signing and Common request payload.

Request example

{
 "id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
 "system": {
 "ver": "1.0",
 "appId": "lcdxxxxxxxxx",
 "sign": "xjhCQBoJ9hRDsCjyDcHjtDNzRZ3ZJezcawsfWeiaoxU=",
 "time": 1706511734,
 "nonce": "f5a1ae2d-c09c-4d39-a744-83a5c2c653c2"
 },
 "params": {
 "token": "<yourAccessToken>",
 "deviceId": "TESTIPC000012345",
 "channelId": "0",
 "properties": {
 "detection.motion.enabled": 1
 }
 }
}

Response data fields

No business fields. On success, code is "0" and data is {}. code="0" means the entire batch succeeded. The contract does not define partial success.

Response example

{
 "id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
 "result": {
 "code": "0",
 "msg": "Operation is successful",
 "data": {}
 }
}

Error codes

This API may return the codes below.

Gateway and device codes: Global return codes.

device.property.get (Read properties)