network.gateway.accessoryLimit (Set accessory add limit property)
network.gateway.accessoryLimit: Set accessory add limit property
network.gateway.accessoryLimit · device scope · permission Config
What it does
Sets the maximum number of accessories a gateway can add. int, 0–999, step 1. Out-of-range values are rejected; the device does not clamp.
Request URL
POST https://openapi-[DataCenter].easy4ip.com/openapi/v2/device.property.set
Minimum permission
The administrator does not need an extra permission on a device they bound. A shared device needs the basic configuration permission. A bound sub-user does not. A sub-account needs Config. Device scope—do not send channelId. Mixing device- and channel-scope properties in one request returns DV2008. A write timeout does not mean the operation did not run.
Request parameters
| Name | Type | Required | Description |
|---|---|---|---|
token | String | yes | Administrator, sub-user, or sub-account accessToken |
deviceId | String | yes | Device serial number |
productId | String | no | Optional. If sent and it does not match the device model → DV2009 |
properties | Object | yes | Key network.gateway.accessoryLimit, int 0–999, step 1 |
For common request fields and signing, see Signing conventions and Common request payload.
Request example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"system": {
"ver": "1.0",
"appId": "lcdxxxxxxxxx",
"sign": "xjhCQBoJ9hRDsCjyDcHjtDNzRZ3ZJezcawsfWeiaoxU=",
"time": 1706511734,
"nonce": "f5a1ae2d-c09c-4d39-a744-83a5c2c653c2"
},
"params": {
"token": "<yourAccessToken>",
"deviceId": "TESTIPC000012345",
"properties": {
"network.gateway.accessoryLimit": 32
}
}
}
Response data fields
On success, code is "0" and data is {}.
Response example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"result": {
"code": "0",
"msg": "Operation is successful",
"data": {}
}
}
Error codes
Gateway and device error codes are in Global return codes.