system.diagnostics.rebootState (Set reboot state)
system.diagnostics.rebootState: Set reboot state
system.diagnostics.rebootState · device scope · permission Config
What it does
Set reboot state. Legal values match Read reboot state. Out-of-range values are rejected (not clamped).
Request URL
POST https://openapi-[DataCenter].easy4ip.com/openapi/v2/device.property.set
Minimum permission
The administrator does not need an extra permission on a device they bound. A shared device needs the basic configuration permission. A bound sub-user does not. A sub-account needs Config. A write timeout does not mean the operation did not run.
Request parameters
| Name | Type | Required | Description |
|---|---|---|---|
token | String | yes | Access token for an administrator, sub-user, or sub-account |
deviceId | String | yes | Device serial number |
productId | String | no | Optional. If sent and it does not match the device model → DV2009 |
properties | Object | yes | Key is system.diagnostics.rebootState, text enum (commonly "0"/"1"/"2"; see get page) |
For common request fields and signing, see Signing conventions and Common request payload.
Request example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"system": {
"ver": "1.0",
"appId": "lcdxxxxxxxxx",
"sign": "xjhCQBoJ9hRDsCjyDcHjtDNzRZ3ZJezcawsfWeiaoxU=",
"time": 1706511734,
"nonce": "f5a1ae2d-c09c-4d39-a744-83a5c2c653c2"
},
"params": {
"token": "<yourAccessToken>",
"deviceId": "TESTIPC000012345",
"properties": {
"system.diagnostics.rebootState": "1"
}
}
}
Response data fields
On success, code is "0" and data is {}.
Response example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"result": {
"code": "0",
"msg": "Operation is successful",
"data": {}
}
}
Error codes
| Code | When |
|---|---|
0 | Success |
SN1001 | Signature error |
TK1002 | Token invalid or expired |
DV2007 | Wrong or missing channelId for scope |
DV2008 | Device and channel properties mixed in one request |
DV2004 | Out-of-range rebootState value |
See Global return codes. All DV20xx: Capability errors.