control.outlet.powerSaving (Get auto power-saving property)
control.outlet.powerSaving: Get auto power-saving property
control.outlet.powerSaving · device scope · permission Config
What it does
Reads auto power-saving policy (control.outlet switching configuration; live power and energy use Outlet metering power.outlet.*). std_powerSaving/133600 is a struct.
Request URL
POST https://openapi-[DataCenter].easy4ip.com/openapi/v2/device.property.get
Minimum permission
The administrator does not need an extra permission on a device they bound. A shared device needs the basic configuration permission. A bound sub-user does not. A sub-account needs Config. Do not send channelId on device-scope capabilities. Mixing device and channel properties in one request returns DV2008.
Request parameters
| Name | Type | Required | Description |
|---|---|---|---|
token | String | yes | Access token for an administrator, sub-user, or sub-account |
deviceId | String | yes | Device serial number |
productId | String | no | Optional. If sent and it does not match the device model → DV2009 |
properties | Array | yes | ["control.outlet.powerSaving"] |
For common request fields and signing, see Signing conventions and Common request payload.
Request example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"system": {
"ver": "1.0",
"appId": "lcdxxxxxxxxx",
"sign": "xjhCQBoJ9hRDsCjyDcHjtDNzRZ3ZJezcawsfWeiaoxU=",
"time": 1706511734,
"nonce": "f5a1ae2d-c09c-4d39-a744-83a5c2c653c2"
},
"params": {
"token": "<yourAccessToken>",
"deviceId": "TESTIPC000012345",
"properties": [
"control.outlet.powerSaving"
]
}
}
Response data fields
The value is in result.data.properties["control.outlet.powerSaving"].
struct members:
| Field | Type | Description |
|---|---|---|
enable | int/enum | Enable: 0 off, 1 on |
powerSet | int | Power threshold, W (0–2000, step 1; TSL std_powerSaving/133600) |
duration | int | Duration, min (0–100000, step 1) |
Response example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"result": {
"code": "0",
"msg": "Operation is successful",
"data": {
"properties": {
"control.outlet.powerSaving": {
"enable": 1,
"powerSet": 5,
"duration": 30
}
}
}
}
}
Error codes
| Code | Meaning | Next step |
|---|---|---|
SN1001 | Signature error | Check sign per Development specification |
TK1002 | Token invalid or expired | Refresh accessToken |
OP1002 | Missing required parameter | Add required fields |
OP1003 | Invalid parameter | Match this page’s parameter table |
OP1009 | Permission denied | Check token and device bind/share grants |
OP1013 | Total call limit exceeded | Reduce call rate |
OP1014 | Daily per-interface limit exceeded | See Interface call limits |
DV1007 | Device offline | Wait until the device is online |
See Return codes · OP/SN/TK for the full catalog.
| Code | Meaning | Next step |
|---|---|---|
DV2003 | Property not on device | Use device.capability.list |
DV2004 | Value out of range | Check properties values |
DV2007 | channelId vs scope mismatch | Required for channel scope; omit for device scope |
DV2008 | Mixed device and channel properties | Split the request |
DV2009 | productId mismatch | Omit or set actual model id |
See Capability errors.
