control.outlet.timerGet (Get timer)
control.outlet.timerGet: Get timer
control.outlet.timerGet · device scope · permission Config
What it does
Queries a single / current timer task; groups with Set timer / Timer delay list and timerFinished / timerFailed. No input—pass inputData as {}.
Request URL
POST https://openapi-[DataCenter].easy4ip.com/openapi/v2/device.service.invoke
Minimum permission
The administrator does not need an extra permission on a device they bound. A shared device needs the basic configuration permission. A bound sub-user does not. A sub-account needs Config. Do not send channelId on device-scope capabilities. Mixing device and channel properties in one request returns DV2008. A timeout does not mean the device did not apply the change.
Request parameters
| Name | Type | Required | Description |
|---|---|---|---|
token | String | yes | Access token for an administrator, sub-user, or sub-account |
deviceId | String | yes | Device serial number |
productId | String | no | Optional. If sent and it does not match the device model → DV2009 |
serviceId | String | yes | control.outlet.timerGet |
inputData | Object | conditional | Pass {} when there is no input |
For common request fields and signing, see Signing conventions and Common request payload.
Request example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"system": {
"ver": "1.0",
"appId": "lcdxxxxxxxxx",
"sign": "xjhCQBoJ9hRDsCjyDcHjtDNzRZ3ZJezcawsfWeiaoxU=",
"time": 1706511734,
"nonce": "f5a1ae2d-c09c-4d39-a744-83a5c2c653c2"
},
"params": {
"token": "<yourAccessToken>",
"deviceId": "TESTIPC000012345",
"serviceId": "control.outlet.timerGet",
"inputData": {}
}
}
Response data fields
Output is in result.data.outputData (GetTimer/28900). Typically includes code and a timers array (elements with id / cron / enable / switch, etc.).
Response example
{
"id": "d5c287b4-5b2f-4f03-baf5-8032c5c354af",
"result": {
"code": "0",
"msg": "Operation is successful",
"data": {
"outputData": {
"code": 0,
"timers": [
{
"id": "1",
"cron": "0 8 * * *",
"enable": 1,
"switch": 1
}
]
}
}
}
}
Error codes
| Code | Meaning | Next step |
|---|---|---|
SN1001 | Signature error | Check sign per Development specification |
TK1002 | Token invalid or expired | Refresh accessToken |
OP1002 | Missing required parameter | Add required fields |
OP1003 | Invalid parameter | Match this page’s parameter table |
OP1009 | Permission denied | Check token and device bind/share grants |
OP1013 | Total call limit exceeded | Reduce call rate |
OP1014 | Daily per-interface limit exceeded | See Interface call limits |
DV1007 | Device offline | Wait until the device is online |
See Return codes · OP/SN/TK for the full catalog.
| Code | Meaning | Next step |
|---|---|---|
DV2003 | Capability not on device | Use device.capability.list |
DV2007 | channelId vs scope mismatch | Required for channel scope; omit for device scope |
DV2008 | Mixed device and channel in one call | Split the request |
DV2009 | productId mismatch | Omit or set actual model id |
DV2011 | No capability permission | See Permission codes |
See Capability errors.